02/26/2021
Inspection, Routine
|
08a - Non-Critical |
Water Quality; Other: Water Quality; Other |
Inspector Comments: The swimming pool water total alkalinity was 50 ppm.
|
09a - Non-Critical |
Deck Areas: Deck Areas |
Inspector Comments: The swimming pool skimmers did not have weir gates installed in them.
|
10a - Non-Critical |
Chemicals: Storage and Handling of Chemicals |
Inspector Comments: Containers of liquid muriatic acid were stored directly above bags of powdered soda ash, sodium bicarb, and calcium chloride. This constitutes a violation of liquid pool chemicals stored above dry pool chemicals, and also acids stored in potential contact with bases.
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: The swimming pool raw water line did not have a vacuum gauge installed upstream of the pool pump.
|
13a - Non-Critical |
Cleaning, Premises Maintained: Hose Bibbs, Pool Cleaning Equipment, Clean Facilities |
Inspector Comments: The hose bib in the pump room was not protected by an atmospheric vacuum breaker.
|
01/15/2020
Inspection, Routine
|
01b - Critical |
Water Quality: Water Testing Equipment |
Inspector Comments: Most of the Taylor pool chemical test reagents that were present in the two test kits were expired.
|
08a - Non-Critical |
Water Quality; Other: Water Quality; Other |
Inspector Comments: The pool water total alkalinity was 60 ppm.
|
09a - Non-Critical |
Deck Areas: Deck Areas |
Inspector Comments: The two pool skimmers were not equipped with weir gates.
|
14c - Non-Critical |
Records and Certifications: Chemical Records Maintained |
Inspector Comments: The operator did not record the swimming pool water calcium hardness, the flow meter reading, and the pool saturation index on any of the available chemical record sheets.
|
01/22/2019
Inspection, Routine
|
01b - Critical |
Water Quality: Water Testing Equipment |
Inspector Comments: The container of R-0870 DPD Powder in the Taylor pool test kit expired on 11/18/2018. Corrected on site.
|
08a - Non-Critical |
Water Quality; Other: Water Quality; Other |
Inspector Comments: The pool total alkalinity was 60 ppm. The pool calcium hardness was 825 ppm.
|
10a - Non-Critical |
Chemicals: Storage and Handling of Chemicals |
Inspector Comments: An open paper bag of sodium bicarbonate, and an open paper bag of soda ash were stored on the floor in the pump room. Separate measuring scoops for the various pool chemicals were not present in the chemical storage area.
|
13a - Non-Critical |
Cleaning, Premises Maintained: Hose Bibbs, Pool Cleaning Equipment, Clean Facilities |
Inspector Comments: The hose bibb inside the pump room door was not protected by an atmospheric vacuum breaker.
|
14c - Non-Critical |
Records and Certifications: Chemical Records Maintained |
Inspector Comments: The pool free chlorine and pH levels were checked once per day in January 2019, rather than three times per day.
|
01/03/2018
Inspection, Routine
|
09a - Non-Critical |
Deck Areas: Deck Areas |
Inspector Comments: A five-foot clearance around the pool was not maintained on the east side of the pool. Chairs blocked access around the east side of the pool.
|
10a - Non-Critical |
Chemicals: Storage and Handling of Chemicals |
Inspector Comments: Several of the pool chemical containers were stored in open bags that were not closed. A bag of sodium bicarbonate and a bag of soda ash were in absorbent containers and were stored on the floor in the mechanical room. Separate measuring scoops were not present in the mechanical room for the various pool chemicals.
|
14c - Non-Critical |
Records and Certifications: Chemical Records Maintained |
Inspector Comments: Pool chemical readings were not checked and recorded regularly in November and December 2017.
|
08/11/2017
Inspection, Routine
|
01a - Critical |
Water Quality: Chemical Quality; Disinfection and pH |
Inspector Comments: Pool pH was greater than 9.
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: The raw water line on the piping system was incorrectly color coded.
|
11e - Non-Critical |
Mechanical Room: Make-Up Water and Cross Connections |
Inspector Comments: A reduced pressure zone assembly back flow preventer was not provided on the auto fill line for the pool.
|
13a - Non-Critical |
Cleaning, Premises Maintained: Hose Bibbs, Pool Cleaning Equipment, Clean Facilities |
Inspector Comments: An atmospheric vacuum breaker was not provided on the hose bib in the pump room.
|