10/19/2021
Inspection, Routine
|
08a - Non-Critical |
Water Quality; Other: Water Quality; Other |
Inspector Comments: Free chlorine in the pool measured 9ppm.
The temperature of the pool water was 70°F.
|
09a - Non-Critical |
Deck Areas: Deck Areas |
Inspector Comments: An inlet cap was missing on the pool side wall.
|
09c - Non-Critical |
Deck Areas: Lighting and Ventilation |
Inspector Comments: Adequate lighting was not provided to the pool pump room.
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: The pool piping system was not correctly color coded, and arrows showing flow direction were not provided.
|
11d - Non-Critical |
Mechanical Room: Clearance, Floor Drains, Equipment Storage |
Inspector Comments: Several pieces of broken and unused equipment were stored in the pump room.
|
13a - Non-Critical |
Cleaning, Premises Maintained: Hose Bibbs, Pool Cleaning Equipment, Clean Facilities |
Inspector Comments:
|
14a - Non-Critical |
Records and Certifications: Equipment Maintained, In Operation |
Inspector Comments: The pool heater was not functioning at the time of inspection.
|
14c - Non-Critical |
Records and Certifications: Chemical Records Maintained |
Inspector Comments: No pool testing records were available at the facility during the inspection.
|
14d - Non-Critical |
Records and Certifications: CPO or Approved Certification |
Inspector Comments: A CPO or equivalent was not on staff at the facility.
|
02/05/2020
Inspection, Routine
|
01b - Critical |
Water Quality: Water Testing Equipment |
Inspector Comments: Several test kit chemical reagents were expired.
|
08a - Non-Critical |
Water Quality; Other: Water Quality; Other |
Inspector Comments: Free chlorine in the pool was 8.0ppm.
|
09a - Non-Critical |
Deck Areas: Deck Areas |
Inspector Comments: Two inlet distribution line caps in the pool were missing.
|
10a - Non-Critical |
Chemicals: Storage and Handling of Chemicals |
Inspector Comments: Acids were stored directly next to bases on the chemical storage shelf in the mechanical room.
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: Directional flow arrows were not provided on all pool pump lines. The suction and return lines for the pool and the spa were not color coded.
|
13a - Non-Critical |
Cleaning, Premises Maintained: Hose Bibbs, Pool Cleaning Equipment, Clean Facilities |
Inspector Comments: The faucet used for hot water filling in the pump room was not provided with an atmospheric vacuum breaker.
|
14c - Non-Critical |
Records and Certifications: Chemical Records Maintained |
Inspector Comments: Written chemical records were not being kept for the pool or the spa.
|
03/12/2019
Inspection, Routine
|
08a - Non-Critical |
Water Quality; Other: Water Quality; Other |
Inspector Comments: The total alkalinity of the swim pool was 50ppm during the routine inspection.
|
09a - Non-Critical |
Deck Areas: Deck Areas |
Inspector Comments: Depth markers not provided, 4 inch numerals, or contrasting color on horizontal walls of the spa.
Weirs and/or float valves in the skimmer were missing.
|
10a - Non-Critical |
Chemicals: Storage and Handling of Chemicals |
Inspector Comments: Chemicals were not kept out of reach of children; ensure door is locked.
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: The raw water line was not color coded yellow on the swim pool or the spa.
The wastewater line was not color coded black on the spa.
Directional arrows were not provided on all plumbing lines.
|
11b - Non-Critical |
Mechanical Room: Filters |
Inspector Comments: A backwash sight glass was not provided on the sand filter for the pool or spa.
|
11d - Non-Critical |
Mechanical Room: Clearance, Floor Drains, Equipment Storage |
Inspector Comments: The mechanical room was accessible to unauthorized persons.
|
14c - Non-Critical |
Records and Certifications: Chemical Records Maintained |
Inspector Comments: Chemical records were not kept up-to-date
pH was not recorded at least three times per day
The disinfectant level was not recorded at least three times per day.
Maintenance procedures were not recorded daily.
The chemical records were not available upon inspection.
The flow meter reading, saturation index, calcium hardness, and total alkalinity were not recorded daily.
|
14d - Non-Critical |
Records and Certifications: CPO or Approved Certification |
Inspector Comments: A CPO or equivalent was not on staff or under contract.
|
03/29/2018
Inspection, Routine
|
01a - Critical |
Water Quality: Chemical Quality; Disinfection and pH |
Inspector Comments: pH in the main pool was lower than 7.2
|
08a - Non-Critical |
Water Quality; Other: Water Quality; Other |
Inspector Comments: Free chlorine measured higher than 5.0 ppm in the pool and the spa. Combined chlorine was higher than 1.0 ppm in the pool. Alkalinity measured lower than 70 ppm in the pool. calcium hardness was higher than 600 ppm in the pool.
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: Flow meters were observed not operational at the time of inspection and turn over rates could not be calculated.
|
14c - Non-Critical |
Records and Certifications: Chemical Records Maintained |
Inspector Comments: Chemical records were not available at the time of inspection.
|
14d - Non-Critical |
Records and Certifications: CPO or Approved Certification |
Inspector Comments: A CPO with a valid and current certification was not available at the time of inspection.
|
03/07/2017
Inspection, Routine
|
01a - Critical |
Water Quality: Chemical Quality; Disinfection and pH |
Inspector Comments: The free chlorine in the spa was lower than 0.4 ppm at the time of inspection (automatic chlorinator was empty). Violation corrected on site.
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: The flow meter for the spa was not operational at the time of inspection and flow rate could not be established.
|
14c - Non-Critical |
Records and Certifications: Chemical Records Maintained |
Inspector Comments: Chemical records for the month of february 2017 were not available at the time of inspection. pH was not logged three times a day. Calcium hardness, alkalinity, flow rate and saturation index were not being logged once a day.
|
08/29/2016
Inspection, Routine
|
08a - Non-Critical |
Water Quality; Other: Water Quality; Other |
Inspector Comments: Saturation index for the spa was +0.7
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: Spa flow meter was not operating at the time of inspection.
|
14c - Non-Critical |
Records and Certifications: Chemical Records Maintained |
Inspector Comments: Pool logs did not include checks of alkalinity, calcium hardness and saturation index once a day.
|