06/23/2021
Inspection, Routine
|
01a - Critical |
Water Quality: Chemical Quality; Disinfection and pH |
Inspector Comments: There was no detectable free chlorine present in the pool.
|
02b - Critical |
Disinfection: Automatic and Continuous Disinfection, Approved |
Inspector Comments: The chlorinator for the pool was disconnected and not in use (chlorine was being hand-fed).
|
09a - Non-Critical |
Deck Areas: Deck Areas |
Inspector Comments: Weir gates were not provided on the pool skimmers.
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: A vacuum gauge was not provided on the suction line prior to the pool circulation pump. A schematic diagram of both piping systems was not posted in the mechanical room. The flow meter for the pool was not operational.
|
11e - Non-Critical |
Mechanical Room: Make-Up Water and Cross Connections |
Inspector Comments: A reduced pressure zone assembly was not provided on the fill line for the pool.
|
14c - Non-Critical |
Records and Certifications: Chemical Records Maintained |
Inspector Comments: Chemical records were not provided onsite.
|
07/10/2019
Inspection, Routine
|
01a - Critical |
Water Quality: Chemical Quality; Disinfection and pH |
Inspector Comments: The pool pH was less than 7.2 ppm.
|
08a - Non-Critical |
Water Quality; Other: Water Quality; Other |
Inspector Comments: The calcium hardness for the spa was 100 ppm. The calcium hardness for the pool was 125 ppm.
|
09a - Non-Critical |
Deck Areas: Deck Areas |
Inspector Comments: Weir gates were missing on the pool and spa skimmers.
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: A schematic diagram was not posted in the mechanical room. The flow meters for both bodies of water were not operational.
|
14c - Non-Critical |
Records and Certifications: Chemical Records Maintained |
Inspector Comments: Chemical records were unavailable at the time of the inspection.
|
14d - Non-Critical |
Records and Certifications: CPO or Approved Certification |
Inspector Comments: A Certified Pool Operator was not provided on staff.
|
06/18/2018
Inspection, Routine
|
01a - Critical |
Water Quality: Chemical Quality; Disinfection and pH |
Inspector Comments: The pH for the spa was below 7.0. The pH for the pool was 7.1.
|
01b - Critical |
Water Quality: Water Testing Equipment |
Inspector Comments: Several chemicals in the test kit were expired.
|
08a - Non-Critical |
Water Quality; Other: Water Quality; Other |
Inspector Comments: Alkalinity was 50 in both the pool and spa. Calcium hardness was 100 in both the pool and spa.
|
09a - Non-Critical |
Deck Areas: Deck Areas |
Inspector Comments: Weir gates were not provided on the skimmers for the pool and spa.
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: The flow meter for the spa was not operational. A schematic diagram of the piping system was not posted in the mechanical room. An emergency shutoff was not provided for the pool in the pool deck area.
|
14c - Non-Critical |
Records and Certifications: Chemical Records Maintained |
Inspector Comments: Chlorine and pH were not checked 3 times daily for both bodies of water. Saturation index, calcium hardness, and alkalinity were not checked daily for both bodies of water.
|
06/19/2017
Inspection, Routine
|
01a - Critical |
Water Quality: Chemical Quality; Disinfection and pH |
Inspector Comments: pH in the pool was 6.9
|
08a - Non-Critical |
Water Quality; Other: Water Quality; Other |
Inspector Comments: The pool water temperature was 76 F.
|
09a - Non-Critical |
Deck Areas: Deck Areas |
Inspector Comments: Weir gates were not provided on the pool and spa skimmers.
|
10a - Non-Critical |
Chemicals: Storage and Handling of Chemicals |
Inspector Comments: Acid was stored next to bases in the mechanical room.
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: Color coding and flow arrows were not provided on both piping systems. A schematic diagram was not posted in the mechanical room. There was no flow meter provided for the spa.
|
11c - Non-Critical |
Mechanical Room: Chemical and Disinfectant Feeders |
Inspector Comments: The chlorine for the pool injected upstream of the heater.
|
14c - Non-Critical |
Records and Certifications: Chemical Records Maintained |
Inspector Comments: Flow meter reading, saturation index, alkalinity, and hardness were not checked daily.
|
06/30/2016
Inspection, Routine
|
01a - Critical |
Water Quality: Chemical Quality; Disinfection and pH |
Inspector Comments: THe pH in the pool was 7.0.
|
03a - Critical |
Water Supply and Wastewater: Waste Disposal |
Inspector Comments: A reduced pressure zone assembly was not provided on the fill line for the pool and spa.
|
08a - Non-Critical |
Water Quality; Other: Water Quality; Other |
Inspector Comments: The alkalinity in the pool was 50, calcium hardness was 100. The alkalinity in the spa was 60, calcium hardness was 120. The saturation index on the pool was -1.2.
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: A schematic diagram of the piping system was not posted. A flow meter was not provided for the spa. The raw water from the pool was not properly color coded yellow.
|
07/09/2015
Inspection, Routine
|
316 - Minor |
Color coded pipes & arrows; guages & flow meter installed; schematic diagram posted, instructions |
Inspector Comments: A schematic diagram was not posted for pump room layout.
|
474 - Major |
Chemical parameters ( Free Chlorine and/or pH) must be within required range; immediate closure |
Inspector Comments: The pool disinfectant measured 0ppm bromine.
|
49 - Minor |
CPO or equivalent; water quality records available; tested at proper frequency; turnover |
Inspector Comments: A CPO was not on staff or contracted.
|