Health Inspection Information

The inspection history for the business you selected is displayed below. Each inspection may have zero or more violations. A health inspection report is a "snapshot" of the day and time of the inspection. On any given day, an establishment could have more or fewer violations than noted here. Inspections are based on regulations to eliminate risk factors for illness or injury. Every violation is coded indicating the degree of risk in causing an illness or injury.

  • Critical, Major, or Foodborne Illness Risk Factor Violations: These violations are more likely than other violations to contribute to illness or injury. Inspectors work with operators to make sure that these violations are corrected whenever feasible before they leave the establishment. A re-inspection may be scheduled to verify compliance.
  • Non-Critical, Minor or Good Retail Practice Violations: These violations are not directly related to the cause of illness or injury, but if uncorrected, could negatively affect the operation of the facility, such as maintenance and cleanliness.

Please Note: Tri-County converted to a new database in July 2013. Any inspections listed prior to July 2013 only display the date and type of inspection, but not the inspector comments because of the database conversion. For inspection reports prior to July 2013 please submit a written request to EHInspections@tchd.org.


Facility Details
Program Pool
Facility Name Cambria Suites
Business Name Cambria Suites
Address 16001 E 40th Ave
Aurora, CO 80011-0820
Phone 303-576-9600

Inspection Details
10/05/2021 Inspection, Pools Chemical only
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: The total alkalinity in the spa measured 50ppm.
02/23/2021 Inspection, Routine
01b - Critical
Water Quality: Water Testing Equipment
Inspector Comments: Several expired chemical testing reagents were located in the pump room. The facility had alternate chemicals available for testing pool water chemistry at the facility.
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: Free chlorine in the spa measured 6ppm. The total alkalinity in the pool and spa measured 60ppm.
11a - Non-Critical
Mechanical Room: Recirculation System, Piping, and Maindrains
Inspector Comments: Vacuum gauges were not present on the raw water lines prior to the pumps on all circulation pumps.
14c - Non-Critical
Records and Certifications: Chemical Records Maintained
Inspector Comments: Disinfectant and pH were not being recorded three times per day for the pool, and every 2 hours in the spa. Total alkalinity, calcium hardness, and saturation index were not being recorded once per day for the pool and spa.
11/17/2020 Inspection, Pools Chemical only
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: The free chlorine in the swimming pool measured 6ppm. The combined chlorine in the spa measured 2.2ppm.
08/18/2020 Inspection, Pools Chemical only
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: Total alkalinity in the spa was 50ppm.
11/05/2019 Inspection, Pools Chemical only
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: The disinfectant level in the swimming pool (bromine) was above 10ppm.
01/29/2019 Inspection, Routine
09a - Non-Critical
Deck Areas: Deck Areas
Inspector Comments: Weir gates in the skimmer were missing for the spa and the swim pool.
10a - Non-Critical
Chemicals: Storage and Handling of Chemicals
Inspector Comments: Acids were stored next to bases (sodium bi sulfate next to soda ash).
11a - Non-Critical
Mechanical Room: Recirculation System, Piping, and Maindrains
Inspector Comments: The raw water line of the swim pool and the spa was not color coded yellow. A pressure vacuum guage was not provided prior to the pump of the swim pool or the spa.
14c - Non-Critical
Records and Certifications: Chemical Records Maintained
Inspector Comments: pH was not recorded at least three times per day The disinfectant level was not recorded at least three times per day. The flow meter reading, saturation index, calcium hardness, or the total alkalinity were not recorded daily.
14d - Non-Critical
Records and Certifications: CPO or Approved Certification
Inspector Comments: A CPO or equivalent staff was not on staff or under contract.
09/18/2018 Inspection, Pools Chemical only
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: The spa temperature was 106F during the routine chemical inspection.
03/29/2018 Inspection, Routine
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: At the time of inspection, in the pool bromine was higher than 5.0 ppm and saturation index was 0.8, in the spa bromine was higher than 10 ppm, alkalinity was lower than 70 ppm, and temperature was higher than 104°F.
11a - Non-Critical
Mechanical Room: Recirculation System, Piping, and Maindrains
Inspector Comments: Unfiltered water was labeled green in the mechanical room (should be yellow prior to the filter).
14c - Non-Critical
Records and Certifications: Chemical Records Maintained
Inspector Comments: pH and disinfectant were not being recorded three times a day for the pool and every two hours for the spa. Alkalinity, calcium hardness and saturation index were not being recorded every day.
14d - Non-Critical
Records and Certifications: CPO or Approved Certification
Inspector Comments: The CPO certification was expired for the CPO in charge.
11/30/2017 Inspection, Follow-Up
11/30/2017 Inspection, Pools Chemical only
01a - Critical
Water Quality: Chemical Quality; Disinfection and pH
Inspector Comments: pH in the spa was lower than 7.0 at the time of inspection.
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: Alkalinity in the spa was 30 ppm at the time of inspection.
03/02/2017 Inspection, Routine
01a - Critical
Water Quality: Chemical Quality; Disinfection and pH
Inspector Comments: pH for the spa was 7.0 at the time oof inspection. Violation corrected on site.
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: At the time of inspection: Bromine was higher than 5.0 ppm in the pool, Alkalinity was 40 ppm in the spa.
11a - Non-Critical
Mechanical Room: Recirculation System, Piping, and Maindrains
Inspector Comments: The flow meter for the spa filtration system was not operational at the time of inspection.
14c - Non-Critical
Records and Certifications: Chemical Records Maintained
Inspector Comments: pH and disinfectant were being recorded only once a day for the pool and the spa. Alkalinity, calcium hardness, flow rate and saturation index were not being recorded in the chemical log.
11/29/2016 Inspection, Pools Chemical only
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: At the time of inspection Bromine in the pool and spa was higher than 5.0 ppm. Temperature in the spa was higher than 104°F.
08/15/2016 Inspection, Routine
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: Calcium hardness in the spa was 140 ppm .
11a - Non-Critical
Mechanical Room: Recirculation System, Piping, and Maindrains
Inspector Comments: The flow meter in the spa filtration system was not operational at the time of inspection.
11d - Non-Critical
Mechanical Room: Clearance, Floor Drains, Equipment Storage
Inspector Comments: The floor in the mechanical room was observed wet at the time of inspection.
12a - Non-Critical
Locker rooms, Restrooms, & Bather Control: Locker rooms, Restrooms, & Bather Control
Inspector Comments: Maximum bather loads were not posted in the swimming area.
14c - Non-Critical
Records and Certifications: Chemical Records Maintained
Inspector Comments: Disinfectant and pH were not checked three times a day for the pool. Alkalinity and calcium hardness were not recorded in the chemical log.
14d - Non-Critical
Records and Certifications: CPO or Approved Certification
Inspector Comments: The CPO certificate on file, available at the time of inspection, was expired.
12/03/2015 Inspection, Pools Chemical only
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: The spa temperature was above 104°F.
06/11/2015 Inspection, Routine
475 - Minor
Pool chemical parameters must be within required range
Inspector Comments: The alkalinity of the spa was below the minimum 70 ppm. The calcium hardness of the spa was below the minimum 150 ppm. The temperature of the spa was above the maximum 104°F.
49 - Minor
CPO or equivalent; water quality records available; tested at proper frequency; turnover
Inspector Comments: pH and chlorine readings were not taken three times per day.
10/16/2014 Inspection, Pools Chemical only
04/10/2014 Inspection, Routine
316 - Minor
Color coded pipes & arrows; guages & flow meter installed; schematic diagram posted, instructions
Inspector Comments: The piping system in the pump room were not properly color coded.
475 - Minor
Pool chemical parameters must be within required range
Inspector Comments: The total alkalinity for the spa was lower than 70 ppm. The temperature for the spa was higher than 104°F
49 - Minor
CPO or equivalent; water quality records available; tested at proper frequency; turnover
Inspector Comments: Pool chemicals were not being checked a minimum of 3 times a day.
10/17/2013 Inspection, Pools Chemical only

Please Note: Tri-County converted to a new database in July 2013. Any inspections listed prior to July 2013 only display the date and type of inspection, but not the inspector comments because of the database conversion. For inspection reports prior to July 2013 please submit a written request to EHInspections@tchd.org.