03/26/2021
Inspection, Routine
|
01b - Critical |
Water Quality: Water Testing Equipment |
Inspector Comments: Multiple testing reagents were expired in the pump room.
|
08a - Non-Critical |
Water Quality; Other: Water Quality; Other |
Inspector Comments: Cyanuric Acid was recorded above 100 ppm for the pool and spa.
Free Chlorine in the spa was recorded above 5 ppm.
|
09a - Non-Critical |
Deck Areas: Deck Areas |
Inspector Comments: Weir Gates were not provided for the pool and spa.
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: The flow meter for the pool and spa were not operational
|
14c - Non-Critical |
Records and Certifications: Chemical Records Maintained |
Inspector Comments: Chlorine and pH were not checked 3 times a day for the pool
Chlorine and pH were not checked every 2 hours for the spa.
|
03/07/2019
Inspection, Routine
|
08a - Non-Critical |
Water Quality; Other: Water Quality; Other |
Inspector Comments: The pool alkalinity was 220ppm. The spa combined chlorine was 1.4ppm. The spa saturation index was +0.7.
|
09a - Non-Critical |
Deck Areas: Deck Areas |
Inspector Comments: The pool or spa skimmers did not have weir gates.
|
10a - Non-Critical |
Chemicals: Storage and Handling of Chemicals |
Inspector Comments: Sodium Bicarbonate in the pump room was not stored in a container with a lid.
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: The pool flow meter was not functioning. A flow meter was not provided for the spa.
|
14c - Non-Critical |
Records and Certifications: Chemical Records Maintained |
Inspector Comments: The pool and spa alkalinity, calcium hardness and saturation index were not being recorded once a day.
|
14d - Non-Critical |
Records and Certifications: CPO or Approved Certification |
Inspector Comments: The facility does not have a Certified Pool Operator on staff.
|
04/12/2018
Inspection, Routine
|
01a - Critical |
Water Quality: Chemical Quality; Disinfection and pH |
Inspector Comments: The pool chlorine was 0.2 ppm.
|
08a - Non-Critical |
Water Quality; Other: Water Quality; Other |
Inspector Comments: The spa temperature was 105°F.
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: One of the pool main drain covers was missing. The pool flow meter was not functioning.
|
14c - Non-Critical |
Records and Certifications: Chemical Records Maintained |
Inspector Comments: The pool disinfectant and pH were not being checked three times a day. The spa disinfectant, pH, and temperature were not being checked every two hours. The pool and spa calcium hardness, alkalinity, and saturation index were not being checked once a day.
|
01/25/2017
Inspection, Routine
|
08a - Non-Critical |
Water Quality; Other: Water Quality; Other |
Inspector Comments: The spa alkalinity was greater than the required 70-180ppm. The spa calcium hardness was greater than the 150-600ppm. The spa saturation index was not between the required range of -0.5 to +0.5.
|
09a - Non-Critical |
Deck Areas: Deck Areas |
Inspector Comments: Weir gates were not provided on the pool and spa skimmers.
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: The pump system schematic drawing was not provided in the pump room. The pool flow meter was not functioning.
|
05/11/2016
Inspection, Routine
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: A schematic drawing was not provided for the pool or spa in the pump room. The flow meters for the pool and spa were not functioning adequately.
|
13a - Non-Critical |
Cleaning, Premises Maintained: Hose Bibbs, Pool Cleaning Equipment, Clean Facilities |
Inspector Comments: The wall and coving in the pump room was in disrepair.
|
14b - Non-Critical |
Records and Certifications: Turnover Requirements |
Inspector Comments: The pool and spa flow meters were not functioning, therefore, a turnover rate was not acquired during the inspection.
|
14c - Non-Critical |
Records and Certifications: Chemical Records Maintained |
Inspector Comments: The facility was only checking the pool and spa disinfectant and pH once a day or less.
|
05/20/2015
Inspection, Routine
|
316 - Minor |
Color coded pipes & arrows; guages & flow meter installed; schematic diagram posted, instructions |
Inspector Comments: The flow meter on the spa was not functioning. No schematic diagram was present in the pump room.
|
318 - Minor |
Floor dry; no unnecessarry equipment, chemicals; no unauthorized persons |
Inspector Comments: The floor of the mechanical room was wet.
|
416j - Major |
Disinfection provided, maintained, proper handling of chemicals:Absorbant chemical containers stored |
Inspector Comments: Chemicals in absorbent containers were not being stored at least 6 inches off the floor.
|
433 - Major |
Meets minimum sanitary standards, unprotected cross connections prohibited: Cross connections |
Inspector Comments: A backflow prevention device was not present on the hose bib in the back storage room.
|
475 - Minor |
Pool chemical parameters must be within required range |
Inspector Comments: The alkalinity in the spa was less than 70ppm. The spa temperature was greater than 104°F.
|
49 - Minor |
CPO or equivalent; water quality records available; tested at proper frequency; turnover |
Inspector Comments: No CPO was available on staff. Chemical reading were not being taken at the proper intervals per section 4.9.
|
04/24/2014
Inspection, Routine
|
316 - Minor |
Color coded pipes & arrows; guages & flow meter installed; schematic diagram posted, instructions |
Inspector Comments: The spa flow meter was not functioning.
|
323 - Minor |
Proper number of swimmers allowed: Proper number of swimmers allowed |
Inspector Comments: The pool and spa capacities were not posted.
|
475 - Minor |
Pool chemical parameters must be within required range |
Inspector Comments: The spa alkalinity was less than 70. The pool saturation index was greater than +0.5.
|