Health Inspection Information

The inspection history for the business you selected is displayed below. Each inspection may have zero or more violations. A health inspection report is a "snapshot" of the day and time of the inspection. On any given day, an establishment could have more or fewer violations than noted here. Inspections are based on regulations to eliminate risk factors for illness or injury. Every violation is coded indicating the degree of risk in causing an illness or injury.

  • Critical, Major, or Foodborne Illness Risk Factor Violations: These violations are more likely than other violations to contribute to illness or injury. Inspectors work with operators to make sure that these violations are corrected whenever feasible before they leave the establishment. A re-inspection may be scheduled to verify compliance.
  • Non-Critical, Minor or Good Retail Practice Violations: These violations are not directly related to the cause of illness or injury, but if uncorrected, could negatively affect the operation of the facility, such as maintenance and cleanliness.

Please Note: Tri-County converted to a new database in July 2013. Any inspections listed prior to July 2013 only display the date and type of inspection, but not the inspector comments because of the database conversion. For inspection reports prior to July 2013 please submit a written request to EHInspections@tchd.org.


Facility Details
Program Pool
Facility Name Bear Creek Village MHP
Business Name Bear Creek Village MHP
Address 3500 S King St
Denver, CO 80236
Phone 303-789-2641

Inspection Details
07/13/2021 Inspection, Follow-Up
07/12/2021 Inspection, Pools Chemical only
01a - Critical
Water Quality: Chemical Quality; Disinfection and pH
Inspector Comments: The free chlorine in the pool was .2 ppm.
06/29/2021 Inspection, Routine
09a - Non-Critical
Deck Areas: Deck Areas
Inspector Comments: Weir gates were not provided on the skimmers.
11a - Non-Critical
Mechanical Room: Recirculation System, Piping, and Maindrains
Inspector Comments: A vacuum gauge was not provided on the suction line prior to the pump. The filtered and heated sections of circulation piping did not have flow arrows provided and were not color coded.
13a - Non-Critical
Cleaning, Premises Maintained: Hose Bibbs, Pool Cleaning Equipment, Clean Facilities
Inspector Comments: The hose bib used for filling the pool did not have an atmospheric vacuum breaker provided.
14c - Non-Critical
Records and Certifications: Chemical Records Maintained
Inspector Comments: Free chlorine and pH were not recorded 3 times daily. Saturation index was not recorded once daily.
07/25/2019 Inspection, Pools Chemical only
06/18/2019 Inspection, Routine
11a - Non-Critical
Mechanical Room: Recirculation System, Piping, and Maindrains
Inspector Comments: A vacuum gauge was not provided on the suction line prior to the pump. The heated water piping from the heater to the pool was not color coded red and did not have flow arrows. An emergency shut off was not provided in the pool deck area.
08/13/2018 Inspection, Pools Chemical only
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: The total alkalinity was 50ppm; less than 70ppm, in the swim pool. The calcium hardness was 100ppm, less than 150ppm, in the swim pool.
05/31/2018 Inspection, Follow-Up
05/31/2018 Inspection, Routine
01a - Critical
Water Quality: Chemical Quality; Disinfection and pH
Inspector Comments: pH was 7.1.
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: The saturation index was -.7.
09a - Non-Critical
Deck Areas: Deck Areas
Inspector Comments: Weir gates were not provided on the skimmers.
09b - Non-Critical
Deck Areas: Steps, Ladders, Diving
Inspector Comments: 2" color contrasting stripping was not provided on the leading edge of each step entering the pool.
10a - Non-Critical
Chemicals: Storage and Handling of Chemicals
Inspector Comments: Open bags of calcium chloride and soda ash were present in the mechanical room.
11a - Non-Critical
Mechanical Room: Recirculation System, Piping, and Maindrains
Inspector Comments: The heated water piping was not color coded red and did not have flow arrows provided.
13a - Non-Critical
Cleaning, Premises Maintained: Hose Bibbs, Pool Cleaning Equipment, Clean Facilities
Inspector Comments: An atmospheric vacuum breaker was not provided on the hose bib used for filling the pool.
07/27/2017 Inspection, Pools Chemical only
06/09/2017 Inspection, Routine
09b - Non-Critical
Deck Areas: Steps, Ladders, Diving
Inspector Comments: 2" color contrasting strips were not provided on the stairs entering the pool.
11a - Non-Critical
Mechanical Room: Recirculation System, Piping, and Maindrains
Inspector Comments: The flow meter was not operational. An emergency shutoff was not provided in the pool deck area.
14c - Non-Critical
Records and Certifications: Chemical Records Maintained
Inspector Comments: Readings for chlorine and pH were not recorded on the record sheets three times daily. Flow meter reading and saturation index were not being checked daily.
11/08/2016 Inspection, Follow-Up
10/04/2016 Inspection, Follow-Up
03a - Critical
Water Supply and Wastewater: Waste Disposal
Inspector Comments: 10/4/16 The back wash line was directly connected to the sewer.
08/18/2016 Inspection, Routine
03a - Critical
Water Supply and Wastewater: Waste Disposal
Inspector Comments: Back wash water discharged directly to the surface of the ground.
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: Chlorine and pH were not checked three times daily.
09a - Non-Critical
Deck Areas: Deck Areas
Inspector Comments: Four inch horizontal depth markers were not provided on the pool deck.
09b - Non-Critical
Deck Areas: Steps, Ladders, Diving
Inspector Comments: Weir gates were not provided on the skimmers. Two inch color contrasting stripping was not provided on the edges of the stairs entering the pool.
10a - Non-Critical
Chemicals: Storage and Handling of Chemicals
Inspector Comments: Liquid chemicals were stored above dry chemicals in the pump room.
11a - Non-Critical
Mechanical Room: Recirculation System, Piping, and Maindrains
Inspector Comments: Piping in the pump room was not properly color coded, and directional flow arrows were not provided. A correct schematic diagram of the piping system was not posted.
11d - Non-Critical
Mechanical Room: Clearance, Floor Drains, Equipment Storage
Inspector Comments: The floor of the pump room was wet due to a leak on the pump.
13a - Non-Critical
Cleaning, Premises Maintained: Hose Bibbs, Pool Cleaning Equipment, Clean Facilities
Inspector Comments: Two atmospheric vacuum breakers were not provided on the y-valve with hose connected used for filling the pool.

Please Note: Tri-County converted to a new database in July 2013. Any inspections listed prior to July 2013 only display the date and type of inspection, but not the inspector comments because of the database conversion. For inspection reports prior to July 2013 please submit a written request to EHInspections@tchd.org.