06/29/2021
Inspection, Routine
|
09a - Non-Critical |
Deck Areas: Deck Areas |
Inspector Comments: Weir gates were not provided on the skimmers.
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: A vacuum gauge was not provided on the suction line prior to the pump. The filtered and heated sections of circulation piping did not have flow arrows provided and were not color coded.
|
13a - Non-Critical |
Cleaning, Premises Maintained: Hose Bibbs, Pool Cleaning Equipment, Clean Facilities |
Inspector Comments: The hose bib used for filling the pool did not have an atmospheric vacuum breaker provided.
|
14c - Non-Critical |
Records and Certifications: Chemical Records Maintained |
Inspector Comments: Free chlorine and pH were not recorded 3 times daily. Saturation index was not recorded once daily.
|
05/31/2018
Inspection, Routine
|
01a - Critical |
Water Quality: Chemical Quality; Disinfection and pH |
Inspector Comments: pH was 7.1.
|
08a - Non-Critical |
Water Quality; Other: Water Quality; Other |
Inspector Comments: The saturation index was -.7.
|
09a - Non-Critical |
Deck Areas: Deck Areas |
Inspector Comments: Weir gates were not provided on the skimmers.
|
09b - Non-Critical |
Deck Areas: Steps, Ladders, Diving |
Inspector Comments: 2" color contrasting stripping was not provided on the leading edge of each step entering the pool.
|
10a - Non-Critical |
Chemicals: Storage and Handling of Chemicals |
Inspector Comments: Open bags of calcium chloride and soda ash were present in the mechanical room.
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: The heated water piping was not color coded red and did not have flow arrows provided.
|
13a - Non-Critical |
Cleaning, Premises Maintained: Hose Bibbs, Pool Cleaning Equipment, Clean Facilities |
Inspector Comments: An atmospheric vacuum breaker was not provided on the hose bib used for filling the pool.
|
06/09/2017
Inspection, Routine
|
09b - Non-Critical |
Deck Areas: Steps, Ladders, Diving |
Inspector Comments: 2" color contrasting strips were not provided on the stairs entering the pool.
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: The flow meter was not operational. An emergency shutoff was not provided in the pool deck area.
|
14c - Non-Critical |
Records and Certifications: Chemical Records Maintained |
Inspector Comments: Readings for chlorine and pH were not recorded on the record sheets three times daily. Flow meter reading and saturation index were not being checked daily.
|
08/18/2016
Inspection, Routine
|
03a - Critical |
Water Supply and Wastewater: Waste Disposal |
Inspector Comments: Back wash water discharged directly to the surface of the ground.
|
08a - Non-Critical |
Water Quality; Other: Water Quality; Other |
Inspector Comments: Chlorine and pH were not checked three times daily.
|
09a - Non-Critical |
Deck Areas: Deck Areas |
Inspector Comments: Four inch horizontal depth markers were not provided on the pool deck.
|
09b - Non-Critical |
Deck Areas: Steps, Ladders, Diving |
Inspector Comments: Weir gates were not provided on the skimmers. Two inch color contrasting stripping was not provided on the edges of the stairs entering the pool.
|
10a - Non-Critical |
Chemicals: Storage and Handling of Chemicals |
Inspector Comments: Liquid chemicals were stored above dry chemicals in the pump room.
|
11a - Non-Critical |
Mechanical Room: Recirculation System, Piping, and Maindrains |
Inspector Comments: Piping in the pump room was not properly color coded, and directional flow arrows were not provided. A correct schematic diagram of the piping system was not posted.
|
11d - Non-Critical |
Mechanical Room: Clearance, Floor Drains, Equipment Storage |
Inspector Comments: The floor of the pump room was wet due to a leak on the pump.
|
13a - Non-Critical |
Cleaning, Premises Maintained: Hose Bibbs, Pool Cleaning Equipment, Clean Facilities |
Inspector Comments: Two atmospheric vacuum breakers were not provided on the y-valve with hose connected used for filling the pool.
|