03/26/2019
Inspection, Routine
|
01 - Foodborne Illness Risk Factors |
Person in charge present, demonstrates knowledge, and performs duties |
Inspector Comments: 2-102.11(C)(7) Demonstration (Pf), 2-102.11(C)(11) Demonstration (Pf):
The person in charge was unable to answer food safety questions related to cold holding, hot holding, and dish washing.
|
10 - Foodborne Illness Risk Factors |
Adequate handwashing sinks properly supplied and accessible |
Inspector Comments: 5-205.11 Using a Handwashing Sink-Operation and Maintenance (Pf):
The hand sink next to the three compartment sink was blocked with debris.
|
36 - Good Retail Practices |
Thermometer provided & accurate |
Inspector Comments: 4-203.11 Temperature Measuring Devices, Food-Accuracy (Pf):
A food probe thermometer capable of measuring between 0-220°F was not available upon inspection.
|
48 - Good Retail Practices |
Warewashing facilities: installed, maintained, & used; test strips |
Inspector Comments: 4-302.14 Sanitizing Solutions, Testing Devices (Pf):
Sanitizer test strips capable of measuring between 0-400 ppm quaternary ammonium sanitizer residue were not available upon inspection.
|
53 - Good Retail Practices |
Toilet facilities: properly constructed, supplied, & cleaned |
Inspector Comments: 6-501.18 Cleaning of Plumbing Fixtures (C):
The hand sink in the mens restroom was soiled with food debris.
|
55 - Good Retail Practices |
Physical facilities installed, maintained, & clean |
Inspector Comments: 6-101.11 Surface Characteristics-Indoor Areas (C):
A hole was located in the wall in the room next to the walk in refrigerator. A hole was located in the ceiling tile above the large reach in freezers. A hole was located in the ceiling in the restroom. Cardboard was used to line the shelves in the walk in refrigerator.
|
03/27/2017
Inspection, Routine
|
03c - Critical, Food Borne Illness Risk |
Food Temperature Control: Hot hold at 135°f or greater |
Inspector Comments: Burritos were 110°F, various sandwiches were 105-108°F, and pizzas were 101°F in the hot box unit by the hot dog roller.
|
03f - Critical |
Food Temperature Control: Food thermometer (probe type) |
Inspector Comments: A probe thermometer reading 0-220°F was not readily available at the facility.
|
05d - Critical |
Water, Sewage, Plumbing Systems: Sewage disposal |
Inspector Comments: The drain line for the walk-in cooler condenser unit was draining into a bucket.
|
07b - Critical |
Pest Control: Pesticide application |
Inspector Comments: An unapproved rodenticide was observed above the mopsink.
|
12b - Non-Critical |
Cleaning Of Equipment & Utensils: Nonfood-contact surfaces |
Inspector Comments: Ice build-up was observed in the ice cream reach-in freezer.
|
14a - Non-Critical |
Physical Facilities: Plumbing: installed, maintained |
Inspector Comments: The faucet on the 3-compartment sink was leaking.
|
14c - Non-Critical |
Physical Facilities: Floors, walls, and ceilings |
Inspector Comments: A ceiling tile above the 3-compartment sink was missing. The light shields in the back storage area were soiled with insect fragments and debris. A wall tile above the walk-in cooler door was missing. The floor corners in the walk-in cooler were soiled with debris. The ceiling in the walk-in cooler was soiled with dust. The ceiling near the back door was in disrepair.
|
14d - Non-Critical |
Physical Facilities: Lighting |
Inspector Comments: A light in the back storage area was not functioning.
|
14g - Non-Critical |
Physical Facilities: Premises maintained |
Inspector Comments: A gap greater than 1/4" was observed between the wall and the back door.
|
14i - Non-Critical |
Physical Facilities: Restroom facilities |
Inspector Comments: The caulking on the toilet was torn. The ceiling in the restroom was in disrepair.
|
03/26/2015
Inspection, Routine
|
06b - Critical, Food Borne Illness Risk |
Hand Washing: Accessible |
Inspector Comments: Several items were stored in the warewashing area handsink making it inaccessible for handwashing.
|
10b - Non-Critical |
Equipment Design, Construction: Nonfood-contact surfaces |
Inspector Comments: The cardboard lining the storage shelves near the 3-compartment sink and in the walk-in cooler was not smooth and easily cleanable.
|
12a - Non-Critical |
Cleaning Of Equipment & Utensils: Food-contact surfaces |
Inspector Comments: Ice build-up was present in the ice cream reach-in freezer.
|
12b - Non-Critical |
Cleaning Of Equipment & Utensils: Nonfood-contact surfaces |
Inspector Comments: The fan guards in the walk-in cooler were soiled with dust.
|
14a - Non-Critical |
Physical Facilities: Plumbing: installed, maintained |
Inspector Comments: The hot water knob on the 3-compartment sink was leaking.
|
14c - Non-Critical |
Physical Facilities: Floors, walls, and ceilings |
Inspector Comments: The floor edges throughout the facility were soiled with debris. The base coving near the 3-compartment sink was missing. The floor in the walk-in cooler was soiled with debris. A wall panel above the walk-in cooler door was missing.
|
14d - Non-Critical |
Physical Facilities: Lighting |
Inspector Comments: A light in the walk-in cooler was not functioning. A light above the 3-compartment sink was not functioning.
|
14g - Non-Critical |
Physical Facilities: Premises maintained |
Inspector Comments: A gap greater than 1/4" was observed between the wall and the back door.
|
03/25/2014
Inspection, Routine
|
03c - Critical, Food Borne Illness Risk |
Food Temperature Control: Hot hold at 135°f or greater |
Inspector Comments: Hot dogs were 115°F - 116°F in the roller.
|
12a - Non-Critical |
Cleaning Of Equipment & Utensils: Food-contact surfaces |
Inspector Comments: The fan guards were dusty in the walk-in cooler.
|
14c - Non-Critical |
Physical Facilities: Floors, walls, and ceilings |
Inspector Comments: The floor was soiled below the display racks in the walk-in cooler. Soda syrup residue was observed on the wall by the water heater.
|