12/03/2019
Inspection, Routine
|
10 - Foodborne Illness Risk Factors |
Adequate handwashing sinks properly supplied and accessible |
Inspector Comments: 5-202.12 Handwashing Sinks, Installation (Pf)
Hot water measured (59°F-60°F) at the hand sink in the mens bathroom.
Hot water measured (59°F-60°F) at the hand sink in the womens bathroom.
Corrective Action: Correct immediately.
|
28 - Foodborne Illness Risk Factors |
Toxic substances properly identified, stored & used |
Inspector Comments: 7-204.11 Sanitizers, Criteria-Chemicals (P)
The sanitizer in the three compartment sink measured greater than 400ppm quaternary ammonia residual.
Corrective action: The person in charge diluted the sanitizer with water to measure 200pm quaternary ammonia residual.
|
51 - Good Retail Practices |
Plumbing installed; proper backflow devices |
Inspector Comments: 5-205.15 System Maintained in Good Repair (C)
The faucet on the hand sink in the mens bathroom was leaking.
The drain pipe connected to the basin of the hand sink next to the first drive thru window was leaking upon inspection.
|
11/17/2017
Inspection, Routine
|
02c - Critical, Food Borne Illness Risk |
Personnel: Hands washed as needed |
Inspector Comments: An employee was observed using hand sanitizer in place of hand washing prior to donning gloves.
|
02e - Critical |
Personnel: Smoking, eating, drinking |
Inspector Comments: Unapproved open top employee beverages and food were present on the back preparation table.
|
06c - Critical, Food Borne Illness Risk |
Hand Washing: Soap and drying devices |
Inspector Comments: Soap dispensers were not functioning at the back hand sink across from the preparation sink and at the front hand sink by the registers.
|
10b - Non-Critical |
Equipment Design, Construction: Nonfood-contact surfaces |
Inspector Comments: The door gaskets were torn on the cook line reach-in refrigerators and freezer.
|
13a - Non-Critical |
Utensils, Single-Service Articles: Utensils provided, used, stored |
Inspector Comments: A spatula was stored in the crevice between the knife rack and wall in the ware washing area.
|
14a - Non-Critical |
Physical Facilities: Plumbing: installed, maintained |
Inspector Comments: The pipe below the cook line hand sink was leaking.
|
14c - Non-Critical |
Physical Facilities: Floors, walls, and ceilings |
Inspector Comments: The wall and ceiling above the reach-in freezer next to the fryers were stained. The wall by the mop sink was in disrepair.
|
11/19/2015
Inspection, Routine
|
05b - Critical |
Water, Sewage, Plumbing Systems: Hot and cold water under pressure |
Inspector Comments: Hot water was not present at the preparation sink.
|
05c - Critical |
Water, Sewage, Plumbing Systems: Backflow, back siphonage |
Inspector Comments: A y-valve shut off was present downstream of the atmospheric vacuum breaker on the mop sink.
|
10b - Non-Critical |
Equipment Design, Construction: Nonfood-contact surfaces |
Inspector Comments: Several gaskets were torn on refrigeration units throughout the facility.
|
12c - Non-Critical |
Cleaning Of Equipment & Utensils: Dishwashing operations |
Inspector Comments: Dishes on the clean dish rack were stacked wet.
|
14a - Non-Critical |
Physical Facilities: Plumbing: installed, maintained |
Inspector Comments: The hot water was leaking on the three compartment sink. The caulking around the mop sink basin was soiled with mold.
|
14c - Non-Critical |
Physical Facilities: Floors, walls, and ceilings |
Inspector Comments: The wall behind the mop was in disrepair and had a large hole.
|
11/24/2014
Inspection, Routine
|
05b - Critical |
Water, Sewage, Plumbing Systems: Hot and cold water under pressure |
Inspector Comments: Hot water was not available at the food preparation sink.
|
05c - Critical |
Water, Sewage, Plumbing Systems: Backflow, back siphonage |
Inspector Comments: A shutoff was present downstream from the back flow prevention device on the mop sink.
|
10b - Non-Critical |
Equipment Design, Construction: Nonfood-contact surfaces |
Inspector Comments: The hose on the mop sink was repaired with plastic. A door gasket on the reach-in freezer by the cook line fryers was torn.
|
14c - Non-Critical |
Physical Facilities: Floors, walls, and ceilings |
Inspector Comments: The floor in the walk-in freezer was soiled with debris.
|
11/06/2013
Inspection, Routine
|
14a - Non-Critical |
Physical Facilities: Plumbing: installed, maintained |
Inspector Comments: The wall caulking of the back drive thru hand sink was in disrepair.
|
14c - Non-Critical |
Physical Facilities: Floors, walls, and ceilings |
Inspector Comments: Several holes were present in the wall above the mop sink.
|
14i - Non-Critical |
Physical Facilities: Restroom facilities |
Inspector Comments: The floor caulking of the toilet in the mens and womens restroom was in disrepair.
|