06/05/2018
Inspection, Routine
|
04b - Critical |
Sanitation: Mechanical |
Inspector Comments: The dishwasher did not have a concentration of at least 50 ppm residual chlorine during the final sanitation rinse.
|
10b - Non-Critical |
Equipment Design, Construction: Nonfood-contact surfaces |
Inspector Comments: The walk-in refrigerator door gasket was torn.
|
11a - Non-Critical |
Testing Devices: Refrigeration units provided with accurate, conspicuous thermometer |
Inspector Comments: The south two door upright reach-in refrigerator thermometer was not accurate.
|
14a - Non-Critical |
Physical Facilities: Plumbing: installed, maintained |
Inspector Comments: The floor sink and the warewashing handsink basin were slow to drain.
|
14d - Non-Critical |
Physical Facilities: Lighting |
Inspector Comments: A ceiling light in the warewashing area was burned out.
|
07/01/2016
Inspection, Routine
|
05b - Critical |
Water, Sewage, Plumbing Systems: Hot and cold water under pressure |
Inspector Comments: Hot water under pressure was not available at the front service area hand sink.
|
07a - Critical |
Pest Control: Evidence of insects or rodents |
Inspector Comments: Several ants were observed around the floor drain under the mechanical dish machine.
|
10b - Non-Critical |
Equipment Design, Construction: Nonfood-contact surfaces |
Inspector Comments: The door gasket on the walk-in cooler was torn.
|
14c - Non-Critical |
Physical Facilities: Floors, walls, and ceilings |
Inspector Comments: Holes in the wall above the three compartment sink were observed.
|
06/26/2015
Inspection, Routine
|
12d - Non-Critical |
Cleaning Of Equipment & Utensils: Wiping cloths |
Inspector Comments: Wiping cloths were stored in a bucket with less than 200 ppm quaternary ammonia sanitizer.
|
14a - Non-Critical |
Physical Facilities: Plumbing: installed, maintained |
Inspector Comments: The faucet handle in the women's rest room was in poor repair.
|
14i - Non-Critical |
Physical Facilities: Restroom facilities |
Inspector Comments: The restroom doors were not self-closing.
|
06/27/2014
Inspection, Routine
|
02e - Critical |
Personnel: Smoking, eating, drinking |
Inspector Comments: An employee beverage was present on the prep-counter at the front entrance to the kitchen prep-area.
|
03f - Critical |
Food Temperature Control: Food thermometer (probe type) |
Inspector Comments: A probe thermometer (0-220°F) was not provided for checking temperatures.
|
05c - Critical |
Water, Sewage, Plumbing Systems: Backflow, back siphonage |
Inspector Comments: The atmospheric vacuum breaker on the mop sink faucet was not functional.
|
10b - Non-Critical |
Equipment Design, Construction: Nonfood-contact surfaces |
Inspector Comments: The clean side of the dish machine drainboard was not caulked to the wall. The prep-sink was not attached and caulked to the wall.
|
11c - Non-Critical |
Testing Devices: Chemical test kits provided and accessible |
Inspector Comments: Test strips were not provided for checking the quat sanitizer.
|
13c - Non-Critical |
Utensils, Single-Service Articles: No reuse of single-service articles |
Inspector Comments: Single-service plastic containers were being reused.
|
14a - Non-Critical |
Physical Facilities: Plumbing: installed, maintained |
Inspector Comments: The back kitchen hand sink was not properly sealed to the wall. The caulking on the mop sink had mold present.
|
14b - Non-Critical |
Physical Facilities: Garbage and refuse |
Inspector Comments: One dumpster lid was open.
|
14c - Non-Critical |
Physical Facilities: Floors, walls, and ceilings |
Inspector Comments: The floor drain in front of the prep-sink was soiled. The floor around the floor drain below the dish machine was peeling upward.
|
07/25/2013
Inspection, Routine
|
02e - Critical |
Personnel: Smoking, eating, drinking |
Inspector Comments: Employee beverages were stored next to food service gloves below the front kitchen prep-counter.
|
05d - Critical |
Water, Sewage, Plumbing Systems: Sewage disposal |
Inspector Comments: The prep-sink drained directly to the floor.
|
06c - Critical, Food Borne Illness Risk |
Hand Washing: Soap and drying devices |
Inspector Comments: Paper towels were not provided at the back kitchen hand sink.
|
10b - Non-Critical |
Equipment Design, Construction: Nonfood-contact surfaces |
Inspector Comments: The door gasket on the walk-in cooler was torn. Packing paper lined the freezer by the prep-sink. The prep-sink was not completely caulked to the wall. The 3-compartment sink was not completely caulked to the wall.
|
12b - Non-Critical |
Cleaning Of Equipment & Utensils: Nonfood-contact surfaces |
Inspector Comments: The door gasket on the small kitchen area refrigerator was soiled.
|
13c - Non-Critical |
Utensils, Single-Service Articles: No reuse of single-service articles |
Inspector Comments: Several single-service sour cream containers were reused to store other food products.
|
14a - Non-Critical |
Physical Facilities: Plumbing: installed, maintained |
Inspector Comments: The atmospheric vacuum breaker on the mop sink faucet leaked and was missing a cap. The sprayer nozzle before the dish machine leaked.
|