02/22/2018
Inspection, Routine
|
05b - Critical |
Water, Sewage, Plumbing Systems: Hot and cold water under pressure |
Inspector Comments: Hot water in the Mens restroom failed to reach a minimum of 100°F. Facilities maintenance was notified during inspection.
|
08a - Critical |
Poisonous Or Toxic Items: Properly stored |
Inspector Comments: A container of soap was stored on top of the dishmachine. Chemical moved to floor under warewashing area.
|
08b - Critical |
Poisonous Or Toxic Items: Properly labeled |
Inspector Comments: A chemical spray bottle stored to the right of the oven was unlabeled as to its contents. Bottle labeled by operator during inspection.
|
13a - Non-Critical |
Utensils, Single-Service Articles: Utensils provided, used, stored |
Inspector Comments: Several utensil drawers in the kitchen were stored in disarray.
|
14a - Non-Critical |
Physical Facilities: Plumbing: installed, maintained |
Inspector Comments: The rinse sprayer at the three compartment sink was not properly installed to be self retracting.
|
14c - Non-Critical |
Physical Facilities: Floors, walls, and ceilings |
Inspector Comments: The ceiling above the dishmachine was in disrepair. The floor seal in the walk in cooler was worn.
|
01/27/2017
Inspection, Routine
|
02c - Critical, Food Borne Illness Risk |
Personnel: Hands washed as needed |
Inspector Comments: Several employees did not wash their hands before donning gloves or between glove changes.
|
02d - Critical, Food Borne Illness Risk |
Personnel: Hygienic practices |
Inspector Comments: An employee was observed blowing into their gloves before putting them on, on two occasions.
|
02g - Critical, Food Borne Illness Risk |
Personnel: Preventing food contamination from bare hands |
Inspector Comments: An employee at the drink station making lemonade touched ready-to-eat, cut lemons with their bare hand.
|
03b - Critical, Food Borne Illness Risk |
Food Temperature Control: Rapidly heat foods to 165°f or greater |
Inspector Comments: Commercially prepared spaghetti sauce in a crock pot was not rapidly reheated to 135°F within two hours for hot holding.
|
03f - Critical |
Food Temperature Control: Food thermometer (probe type) |
Inspector Comments: The food probe thermometer was not functioning; facility was instructed to purchase a food probe thermometer that measures 0-220°F in 2°F increments.
|
05b - Critical |
Water, Sewage, Plumbing Systems: Hot and cold water under pressure |
Inspector Comments: Hot water at the kitchen hand sink (74°F) and at both women's restroom hand sinks (93-95°F) did not reach at least 100°F.
|
10a - Non-Critical |
Equipment Design, Construction: Food-contact surfaces |
Inspector Comments: Three crock pots in the kitchen were being used to reheat and hot hold foods and were labeled for household use only.
|
11a - Non-Critical |
Testing Devices: Refrigeration units provided with accurate, conspicuous thermometer |
Inspector Comments: The bottom hot box thermometer read 100°F with an internal temperature of at least 170°F.
|
12b - Non-Critical |
Cleaning Of Equipment & Utensils: Nonfood-contact surfaces |
Inspector Comments: The ice machine discharge pipe where water drains was soiled with slime mold.
|
12c - Non-Critical |
Cleaning Of Equipment & Utensils: Dishwashing operations |
Inspector Comments: Clean dishes were observed drying on dish cloths on the dish cart.
|
13a - Non-Critical |
Utensils, Single-Service Articles: Utensils provided, used, stored |
Inspector Comments: Forks and spoons in the utensil cart in the kitchen annex room were stored with the food contact surfaces presented to the employee or consumer rather than the handle.
|
14c - Non-Critical |
Physical Facilities: Floors, walls, and ceilings |
Inspector Comments: The floor drain under the ice machine was soiled with grime and slime mold.
|
03/01/2016
Inspection, Routine
|
10b - Non-Critical |
Equipment Design, Construction: Nonfood-contact surfaces |
Inspector Comments: Several raw wood shelves were being used for utensil storage in the dry storage room.
|
14c - Non-Critical |
Physical Facilities: Floors, walls, and ceilings |
Inspector Comments: The floor drain under the three compartment sink was soiled with debris.
|
14d - Non-Critical |
Physical Facilities: Lighting |
Inspector Comments: Several lights in the kitchen were not functioning.
|