Health Inspection Information

The inspection history for the business you selected is displayed below. Each inspection may have zero or more violations. A health inspection report is a "snapshot" of the day and time of the inspection. On any given day, an establishment could have more or fewer violations than noted here. Inspections are based on regulations to eliminate risk factors for illness or injury. Every violation is coded indicating the degree of risk in causing an illness or injury.

  • Critical, Major, or Foodborne Illness Risk Factor Violations: These violations are more likely than other violations to contribute to illness or injury. Inspectors work with operators to make sure that these violations are corrected whenever feasible before they leave the establishment. A re-inspection may be scheduled to verify compliance.
  • Non-Critical, Minor or Good Retail Practice Violations: These violations are not directly related to the cause of illness or injury, but if uncorrected, could negatively affect the operation of the facility, such as maintenance and cleanliness.

Please Note: Tri-County converted to a new database in July 2013. Any inspections listed prior to July 2013 only display the date and type of inspection, but not the inspector comments because of the database conversion. For inspection reports prior to July 2013 please submit a written request to EHInspections@tchd.org.


Facility Details
Program Pool
Facility Name 24 Hour Fitness 351
Business Name 24 Hour Fitness 351
Address 4120 E Alameda Ave
Glendale, CO 80246
Phone 303-377-4424

Inspection Details
10/26/2021 Inspection, Pools Chemical only
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: The alkalinity was 50 ppm in both the pool and spa. The calcium hardness in the spa was 100 ppm. The saturation index for both bodies of water was -.7.
03/02/2021 Inspection, Routine
01b - Critical
Water Quality: Water Testing Equipment
Inspector Comments: One expired DPD titrant was present in the pool test kit used by the facility.
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: Alkalinity in the pool was 50 ppm. Calcium hardness in the pool was 650 ppm. The free chlorine in the spa was greater than 5.0 ppm.
09a - Non-Critical
Deck Areas: Deck Areas
Inspector Comments: Weir gates were not provided on the pool and spa skimmers. The spa was provided with only one skimmer.
11a - Non-Critical
Mechanical Room: Recirculation System, Piping, and Maindrains
Inspector Comments: The flow meters for the pool and spa were not operational. A schematic diagram of both piping systems was not posted in the mechanical room. Vacuum gauges were not provided on the pool and spa suction lines prior to the circulation pumps.
14c - Non-Critical
Records and Certifications: Chemical Records Maintained
Inspector Comments: Chemical parameter records were not present onsite.
10/15/2020 Inspection, Pools Chemical only
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: The pool total alkalinity was 40 ppm. The pool water temperature was 76 degrees F.
03/09/2020 Inspection, Routine
01b - Critical
Water Quality: Water Testing Equipment
Inspector Comments: One expired pool testing reagent was stored in the mechanical room.
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: The alkalinity in the pool was 50.
09a - Non-Critical
Deck Areas: Deck Areas
Inspector Comments: Weir gates were not provided on the pool and spa skimmers.
11a - Non-Critical
Mechanical Room: Recirculation System, Piping, and Maindrains
Inspector Comments: The spa had only one skimmer provided. Vacuum gauges were not provided on the suction lines prior to the pump for both the pool and spa circulation pumps.
14c - Non-Critical
Records and Certifications: Chemical Records Maintained
Inspector Comments: Free chlorine, temperature, and pH were not recorded once every two hours for the spa. Flow meter reading and saturation index were not recorded daily for the spa. ORP was not recorded 3 times daily for the pool. Flow meter reading and saturation index were not recorded daily for the pool.
12/05/2019 Inspection, Pools Chemical only
01a - Critical
Water Quality: Chemical Quality; Disinfection and pH
Inspector Comments: The pH in the spa was less than 7.2.
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: Free chlorine in the spa was 5.2 ppm. Combined chlorine in the spa was 2.8 ppm. Alkalinity in the pool and spa was 50 ppm.
01/31/2019 Inspection, Routine
01a - Critical
Water Quality: Chemical Quality; Disinfection and pH
Inspector Comments: The spa pH was below 7.0.
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: The combined chlorine in the spa was 4.2 ppm. The free chlorine in the pool was 6.2. The alkalinity in the spa was 50.
09a - Non-Critical
Deck Areas: Deck Areas
Inspector Comments: Only one skimmer was provided for the spa. Weir gates were not provided on the pool and spa skimmers.
11a - Non-Critical
Mechanical Room: Recirculation System, Piping, and Maindrains
Inspector Comments: The flow meters for the spa filtration system were improperly located and were not functioning. The flow meter for the pool filtration system was not functioning.
14c - Non-Critical
Records and Certifications: Chemical Records Maintained
Inspector Comments: Chemical records were not available at the facility for the pool or spa.
10/22/2018 Inspection, Pools Chemical only
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: The alkalinity in both the pool and spa was 50 ppm.
02/07/2018 Inspection, Routine
01b - Critical
Water Quality: Water Testing Equipment
Inspector Comments: Two expired testing bottles of sodium thiosulfate were present in the mechanical room.
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: Alkalinity in the pool was 40.
09a - Non-Critical
Deck Areas: Deck Areas
Inspector Comments: Weir gates were not provided on the pool and spa skimmers.
10a - Non-Critical
Chemicals: Storage and Handling of Chemicals
Inspector Comments: Separate measuring scoops for each chemical were not provided.
11a - Non-Critical
Mechanical Room: Recirculation System, Piping, and Maindrains
Inspector Comments: The spa flow meter was improperly located (locate flow meters on an 8 foot section of pipe downstream of the heater, and prior to any chemical injections). A schematic drawing of the pool and spa piping systems was not posted in the mechanical room. The circulation pump for the spa leaked.
14c - Non-Critical
Records and Certifications: Chemical Records Maintained
Inspector Comments: Spa chemical parameters were not checked every two hours, pool chemical parameters were not checked three times a day. For the spa, check chlorine and pH every two hours, all other parameters once a day. For the pool check chlorine and pH three times a day, all other parameters once a day.
09/12/2017 Inspection, Pools Chemical only
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: Alkalinity in the spa was 40. Alkalinity in the pool was 60.
01/18/2017 Inspection, Routine
01a - Critical
Water Quality: Chemical Quality; Disinfection and pH
Inspector Comments: The pH on the spa was 7.0.
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: Alkalinity in the pool was 60. Alkalinity in the spa was 30. Saturation index on the spa was -.6. The spa temperature was 105 F.
09a - Non-Critical
Deck Areas: Deck Areas
Inspector Comments: Weir gates were not provided on the pool and spa skimmers.
11a - Non-Critical
Mechanical Room: Recirculation System, Piping, and Maindrains
Inspector Comments: Schematic diagrams of the pool and spa piping systems were not posted. The flow meter for the spa was installed in an incorrect location (flow meters should be placed on the heated water line prior to injection of chemicals, and away from elbows).
14c - Non-Critical
Records and Certifications: Chemical Records Maintained
Inspector Comments: The following chemical parameters were not checked daily for both bodies of water: saturation index, flow meter reading, calcium hardness, alkalinity. Chlorine and pH were not checked every two hours on the spa. Chlorine and pH were not checked 3 times daily on the pool.
10/27/2016 Inspection, Pools Chemical only
01a - Critical
Water Quality: Chemical Quality; Disinfection and pH
Inspector Comments: pH in the spa was 7.0.
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: Alkalinity in the spa was 20, saturation index in the spa was -1.1.
05/04/2016 Inspection, Routine
01a - Critical
Water Quality: Chemical Quality; Disinfection and pH
Inspector Comments: The pH in the spa was 6.8.
08a - Non-Critical
Water Quality; Other: Water Quality; Other
Inspector Comments: Alkalinity in the pool was 40 ppm. Saturation index in the pool was -.7. Calcium hardness in the spa was 140. Alkalinity in the spa was 20.
11a - Non-Critical
Mechanical Room: Recirculation System, Piping, and Maindrains
Inspector Comments: A schematic diagram was not posted in the pump room.
14c - Non-Critical
Records and Certifications: Chemical Records Maintained
Inspector Comments: Chemical records were not taken 3 times daily for the pool and spa on 5/3/16.
12/10/2014 Inspection, Pools Chemical only
475 - Minor
Pool chemical parameters must be within required range
Inspector Comments: The calcium hardness on the spa was 80 ppm.
06/17/2014 Inspection, Routine
312 - Minor
Filter design, turnover, gauges, backwash sightglass, backwash line, sand specifications, data plate
Inspector Comments: The flow meter on the spa and pool were not operating.
316 - Minor
Color coded pipes & arrows; guages & flow meter installed; schematic diagram posted, instructions
Inspector Comments: A schematic diagram of the pump room was not provided. The pipes in the pump room were not color coded.
475 - Minor
Pool chemical parameters must be within required range
Inspector Comments: The temperature of the spa was 107 degrees F. The total alkalinity of the spa was 50 ppm. The calcium hardness of the pool was 120 ppm. The calcium hardness of the spa was 80 ppm.

Please Note: Tri-County converted to a new database in July 2013. Any inspections listed prior to July 2013 only display the date and type of inspection, but not the inspector comments because of the database conversion. For inspection reports prior to July 2013 please submit a written request to EHInspections@tchd.org.